| Beamline. Beamline number. Used for getting the shutter status if the commands startup or shutdown are called. |
| BraggDevice. Name of the FMBOxfDCMMotor tango device corresponding to the Bragg Motor. |
| BraggOffsetC0. UnitCalibration to be written to the Bragg Motor using the ChangeCrystalAndRecalibrate command for changing to crystal 0. |
| BraggOffsetC1. UnitCalibration to be written to the Bragg Motor using the ChangeCrystalAndRecalibrate command for changing to crystal 1. |
| BraggOffsetC2. UnitCalibration to be written to the Bragg Motor using the ChangeCrystalAndRecalibrate command for changing to crystal 2. |
| Bragg2Device. Name of the FMBOxfDCMMotor tango device corresponding to the 2nd. Bragg Motor in the DCM GKSS monochromator (only used for version 10). |
| Bragg2OffsetC0. UnitCalibration to be written to the Bragg Motor in the DCM GKSS monochromator (only used for version 10) using the ChangeCrystalAndRecalibrate command for changing to crystal 0. |
| Bragg2OffsetC1. UnitCalibration to be written to the Bragg Motor in the DCM GKSS monochromator (only used for version 10) using the ChangeCrystalAndRecalibrate command for changing to crystal 1. |
| Bragg2OffsetC2. UnitCalibration to be written to the Bragg Motor in the DCM GKSS monochromator (only used for version 10) using the ChangeCrystalAndRecalibrate command for changing to crystal 2. |
| CrystalCutGap. Value of the gap when the crystal cut is used (crystal 2). Only used with crystal 2 for computing the ExitOffset as a function of the Bragg angle. |
| DCrystalSI111. Lattice spacing for SI111 crystal. If value is not set or set to 0 or negative, a default value is taken. |
| DCrystalSI311. Lattice spacing for SI311 crystal. If value is not set or set to 0 or negative, a default value is taken. |
| FMBOxfDCMCtrlDevice. Name of the FMBOxfDCMCtrl tango device making the connection to the socket. Not used for the petra3 extension beamlines. |
| FMBOxfDCMCtrlDevice2. Name of the a second FMBOxfDCMCtrl tango device for the case of having more motors (only used for versions bigger than 9). |
| LongitudinalDevice. Name of the FMBOxfDCMMotor tango device corresponding to the longitudinal motor in the DCM GKSS monochromator (only used for version 10). |
| LongitudinalOffsetC0. UnitCalibration to be written to the longitudinal Motor in the DCM GKSS monochromator (only used for version 10) using the ChangeCrystalAndRecalibrate command for changing to crystal 0. |
| LongitudinalOffsetC1. UnitCalibration to be written to the longitudinal Motor in the DCM GKSS monochromator (only used for version 10) using the ChangeCrystalAndRecalibrate command for changing to crystal 1. |
| LongitudinalOffsetC2. UnitCalibration to be written to the longitudinal Motor in the DCM GKSS monochromator (only used for version 10) using the ChangeCrystalAndRecalibrate command for changing to crystal 2. |
| ParDevice. Name of the FMBOxfDCMMotor tango device corresponding to the parallel motor. Only for versions smaller than 10. |
| ParOffsetC0. UnitCalibration to be written to the Parallel Motor using the ChangeCrystalAndRecalibrate command for changing to crystal 0. Only for versions smaller than 10. |
| ParOffsetC1. UnitCalibration to be written to the Parallel Motor using the ChangeCrystalAndRecalibrate command for changing to crystal 1. Only for versions smaller than 10. |
| ParOffsetC2. UnitCalibration to be written to the Parallel Motor using the ChangeCrystalAndRecalibrate command for changing to crystal 2. Only for versions smaller than 10. |
| PerpDevice. Name of the FMBOxfDCMMotor tango device corresponding to the perpendicular motor. Only for versions smaller than 10. |
| PerpOffsetC0. UnitCalibration to be written to the Perpendicular Motor using the ChangeCrystalAndRecalibrate command for changing to crystal 0. Only for versions smaller than 10. |
| PerpOffsetC1. UnitCalibration to be written to the Perpendicular Motor using the ChangeCrystalAndRecalibrate command for changing to crystal 1. Only for versions smaller than 10. |
| PerpOffsetC2. UnitCalibration to be written to the Perpendicular Motor using the ChangeCrystalAndRecalibrate command for changing to crystal 2. Only for versions smaller than 10. |
| SimulationMode. 0 real mode, 1 simulation mode. |
| Version. 0 -> old PMAC software, 1 -> new PMAC software, 2 -> new PMAC software with old conversion factors (p10), 10 -> DCM from GKSS, different energy calculation, 11 -> SBM from GKSS, different energy calculation. For the P3 extension beamlines any number lower than 9 can be used. |