C400Pyramid Class Attributes
Name
Inherited
Abstract
Attr. type
R/W type
Data type
Level
Description
DAC1 false false Scalar READ_WRITE Tango::DEV_DOUBLE OPERATOR Analog output
DAC2 false false Scalar READ_WRITE Tango::DEV_DOUBLE OPERATOR Analog output
DAC3 false false Scalar READ_WRITE Tango::DEV_DOUBLE OPERATOR Analog output
DAC4 false false Scalar READ_WRITE Tango::DEV_DOUBLE OPERATOR Analog output
Deadtime false false Scalar READ_WRITE Tango::DEV_DOUBLE OPERATOR Deadtime correction to be applied to the
incoming counts for all channels.
DHI1 false false Scalar READ_WRITE Tango::DEV_DOUBLE OPERATOR Discriminator high level
DHI2 false false Scalar READ_WRITE Tango::DEV_DOUBLE OPERATOR Discriminator high level
DHI3 false false Scalar READ_WRITE Tango::DEV_DOUBLE OPERATOR Discriminator high level
DHI4 false false Scalar READ_WRITE Tango::DEV_DOUBLE OPERATOR Discriminator high level
DLO1 false false Scalar READ_WRITE Tango::DEV_DOUBLE OPERATOR Discriminator low level
DLO2 false false Scalar READ_WRITE Tango::DEV_DOUBLE OPERATOR Discriminator low level
DLO3 false false Scalar READ_WRITE Tango::DEV_DOUBLE OPERATOR Discriminator low level
DLO4 false false Scalar READ_WRITE Tango::DEV_DOUBLE OPERATOR Discriminator low level
Period false false Scalar READ_WRITE Tango::DEV_DOUBLE OPERATOR Integration period
Polarity1 false false Scalar READ_WRITE Tango::DEV_STRING OPERATOR Polarity (N/P)
Polarity2 false false Scalar READ_WRITE Tango::DEV_STRING OPERATOR Polarity (N/P)
Polarity3 false false Scalar READ_WRITE Tango::DEV_STRING OPERATOR Polarity (N/P)
Polarity4 false false Scalar READ_WRITE Tango::DEV_STRING OPERATOR Polarity (N/P)
Counts1 false false Scalar READ Tango::DEV_LONG OPERATOR
Counts2 false false Scalar READ Tango::DEV_LONG OPERATOR
Counts3 false false Scalar READ Tango::DEV_LONG OPERATOR
Counts4 false false Scalar READ Tango::DEV_LONG OPERATOR
HV1 false false Scalar READ Tango::DEV_DOUBLE OPERATOR High voltage readback ADCs.
HV2 false false Scalar READ Tango::DEV_DOUBLE OPERATOR High voltage readback ADCs.
HV3 false false Scalar READ Tango::DEV_DOUBLE OPERATOR High voltage readback ADCs.
HV4 false false Scalar READ Tango::DEV_DOUBLE OPERATOR High voltage readback ADCs.
DigitalStatusBits false false Scalar READ Tango::DEV_LONG OPERATOR 0->connected, 1->pending/busy.2->error,6->urgent device error,
9->starting up, 16->measuring.
TriggerModeStr false false Scalar READ Tango::DEV_STRING OPERATOR
TriggerMode false false Scalar READ_WRITE Tango::DEV_LONG OPERATOR 0->CUSTom, 1-> INTernal, 2->EXTERNAL_START, 3->EXTERNAL_STARTSTOP,
4->EXTERNAL_START_HOLD,5->EXTERNAL_WINDOWED, 6->DISCRIMINATOR_SWEEP
TriggerPolarity false false Scalar READ_WRITE Tango::DEV_LONG OPERATOR External gate polarity (external trigger only). 0 =
rising edge, 1 = falling edge (invert BNC trigger)
TriggerSourceStart false false Scalar READ_WRITE Tango::DEV_STRING OPERATOR The start trigger source. Used in CUSTom,
EXTERNAL_START, EXTERNAL_STARTSTOP,
EXTERNAL_START_HOLD, and EXTERNAL_WINDOWED modes.
INTernal or BNC
TriggerSourceStop false false Scalar READ_WRITE Tango::DEV_STRING OPERATOR The stop trigger source. Used in CUSTom,
and EXTERNAL_STARTSTOP modes.
INTernal or BNC
TriggerSourcePause false false Scalar READ_WRITE Tango::DEV_STRING OPERATOR The pause/burst trigger source. Used in CUSTom,
and EXTERNAL_WINDOWED modes.
INTernal or BNC
ScanStartV false false Scalar READ_WRITE Tango::DEV_DOUBLE OPERATOR Used by scanning (StartScan command)
ScanStopV false false Scalar READ_WRITE Tango::DEV_DOUBLE OPERATOR Used by scanning (StartScan command)
ScanWindowV false false Scalar READ_WRITE Tango::DEV_DOUBLE OPERATOR Used by scanning (StartScan command)
ScanPeriod false false Scalar READ_WRITE Tango::DEV_DOUBLE OPERATOR Used by scanning (StartScan command)
HIVMax1 false false Scalar READ_WRITE Tango::DEV_DOUBLE OPERATOR Set (query) maximum allowable external high voltage setting. This is a software enforced limit.
HIVMax2 false false Scalar READ_WRITE Tango::DEV_DOUBLE OPERATOR Set (query) maximum allowable external high voltage setting. This is a software enforced limit.
HIVMax3 false false Scalar READ_WRITE Tango::DEV_DOUBLE OPERATOR Set (query) maximum allowable external high voltage setting. This is a software enforced limit.
HIVMax4 false false Scalar READ_WRITE Tango::DEV_DOUBLE OPERATOR Set (query) maximum allowable external high voltage setting. This is a software enforced limit.
HIVSUP1 false false Scalar READ Tango::DEV_DOUBLE OPERATOR Query maximum allowable external high voltage setting in volts
for each channel, as determined by the installed HV module.
HIVSUP2 false false Scalar READ Tango::DEV_DOUBLE OPERATOR Query maximum allowable external high voltage setting in volts
for each channel, as determined by the installed HV module.
HIVSUP3 false false Scalar READ Tango::DEV_DOUBLE OPERATOR Query maximum allowable external high voltage setting in volts
for each channel, as determined by the installed HV module.
HIVSUP4 false false Scalar READ Tango::DEV_DOUBLE OPERATOR Query maximum allowable external high voltage setting in volts
for each channel, as determined by the installed HV module.
HIVVOL1 false false Scalar READ_WRITE Tango::DEV_DOUBLE OPERATOR Set (query) the auxiliary (external) high voltage setting.
HIVVOL2 false false Scalar READ_WRITE Tango::DEV_DOUBLE OPERATOR Set (query) the auxiliary (external) high voltage setting.
HIVVOL3 false false Scalar READ_WRITE Tango::DEV_DOUBLE OPERATOR Set (query) the auxiliary (external) high voltage setting.
HIVVOL4 false false Scalar READ_WRITE Tango::DEV_DOUBLE OPERATOR Set (query) the auxiliary (external) high voltage setting.
HIVEnable1 false false Scalar READ_WRITE Tango::DEV_LONG OPERATOR Enable/disable (query) the auxiliary (external) high voltage power supply.
HIVEnable2 false false Scalar READ_WRITE Tango::DEV_LONG OPERATOR Enable/disable (query) the auxiliary (external) high voltage power supply.
HIVEnable3 false false Scalar READ_WRITE Tango::DEV_LONG OPERATOR Enable/disable (query) the auxiliary (external) high voltage power supply.
HIVEnable4 false false Scalar READ_WRITE Tango::DEV_LONG OPERATOR Enable/disable (query) the auxiliary (external) high voltage power supply.





There is no dynamic attribute defined.