I404 Class Attributes
Name
Inherited
Abstract
Attr. type
R/W type
Data type
Level
Description
Calib_source false false Scalar READ_WRITE Tango::DEV_LONG OPERATOR set/query internal calibration source state, 0 - off,\n1 - to channel 1, etc.
Conf_capacitor false false Scalar READ_WRITE Tango::DEV_LONG OPERATOR set feedback capacitor 0 - 100 pF, 1 - 3300 pF
Conf_hv_max false false Scalar READ_WRITE Tango::DEV_LONG OPERATOR set maximum allowable hv setting in volts
Conf_intavg false false Scalar READ_WRITE Tango::DEV_LONG OPERATOR the number of integrations to average per reading, 1 to 15
Conf_hv_set false false Scalar READ_WRITE Tango::DEV_LONG OPERATOR set the external hv in volts
Conf_monitor false false Scalar READ_WRITE Tango::DEV_LONG OPERATOR thset the position function that is performed internally\nby the I404 and the signals that are put out on the analog\nvoltage and frequency monitor\n1 no position calculation\n2 quadrant mode calculations\n3 split mode calculations
Conf_period false false Scalar READ_WRITE Tango::DEV_FLOAT OPERATOR tthe integration period in seconds
Conf_pos_polarity false false Scalar READ_WRITE Tango::DEV_LONG OPERATOR set/query the polarity of the current readings used for \nthe calculations 0 - +ve, 1 - -ve
Conf_pos_threshold false false Scalar READ_WRITE Tango::DEV_FLOAT OPERATOR set/query threshold (in per cent of full current scale in
use) for data to be included in position calculations
Conf_range false false Scalar READ_WRITE Tango::DEV_FLOAT OPERATOR set/query a full scale current range in amps, integration\nperiod and capacitor selection are calculated by the I404
Conf_readavg false false Scalar READ_WRITE Tango::DEV_LONG OPERATOR set/query the number of adc readings to be taken in\neach integration period
Conf_resolution false false Scalar READ_WRITE Tango::DEV_LONG OPERATOR set/query the number of bits of effective resolution, 16 - 20,\nthe i404 calculates the number of integration periods and\nadc readings per integration
Read_current1 false false Scalar READ Tango::DEV_FLOAT OPERATOR query current reading of channel 1
Read_current2 false false Scalar READ Tango::DEV_FLOAT OPERATOR query current reading of channel 2
Read_current3 false false Scalar READ Tango::DEV_FLOAT OPERATOR query current reading of channel 3
Read_current4 false false Scalar READ Tango::DEV_FLOAT OPERATOR query current reading of channel 4
Read_integrationtime false false Scalar READ Tango::DEV_FLOAT OPERATOR integration time used
Read_hv false false Scalar READ Tango::DEV_FLOAT OPERATOR read hv output sense
Read_position_x false false Scalar READ Tango::DEV_FLOAT OPERATOR perform position calculation in configured mode\n
Read_position_y false false Scalar READ Tango::DEV_FLOAT OPERATOR perform position calculation in configured mode\n
Syst_frequency false false Scalar READ_WRITE Tango::DEV_LONG OPERATOR set/query the dominant noise frequency in Hz to be\nsuppressed in the calibration routine, 50 or 60 Hz\n
Syst_save false false Scalar READ_WRITE Tango::DEV_LONG OPERATOR 0 do not go to safe state when disconnected, 1 - go to \nsafe state when disconnected (hv off)\n
Syst_serial false false Scalar READ Tango::DEV_LONG OPERATOR query the system serial number\n
Position_x false false Scalar READ Tango::DEV_FLOAT OPERATOR x-position, in standard P-3 coordinate frame\n
Position_y false false Scalar READ Tango::DEV_FLOAT OPERATOR y-position, in standard P-3 coordinate frame\n
Factor_x false false Scalar READ_WRITE Tango::DEV_FLOAT OPERATOR position_x = read_position_x * factor_x \n
Factor_y false false Scalar READ_WRITE Tango::DEV_FLOAT OPERATOR position_y = read_position_y * factor_y \n
Conf_frequency false false Scalar READ_WRITE Tango::DEV_LONG OPERATOR Set (query) the mapping of the frequency monitor outputs when
they are showing current.
0 = The absolute value of the
selected signal is mapped to the
frequency monitor output
1 Positive values only are mapped
2 = Negative values only are
mapped
PosAndAvgCurr false false Spectrum READ Tango::DEV_DOUBLE OPERATOR





There is no dynamic attribute defined.