Keithley3706 Class Attributes
Name
Inherited
Abstract
Attr. type
R/W type
Data type
Level
Description
Configuration false false Scalar READ_WRITE Tango::DEV_STRING OPERATOR Get/Set dmm.func (temperature or resistance)
Counts false false Scalar READ_WRITE Tango::DEV_LONG OPERATOR Get/Set scan.measurecount
ChList false false Scalar READ_WRITE Tango::DEV_STRING OPERATOR List of channels that will be use in the measurement.
NbChannels false false Scalar READ_WRITE Tango::DEV_LONG OPERATOR Nb of open channels.
ValueCh1 false false Scalar READ Tango::DEV_DOUBLE OPERATOR
ValueCh2 false false Scalar READ Tango::DEV_DOUBLE OPERATOR
ValueCh3 false false Scalar READ Tango::DEV_DOUBLE OPERATOR
ValueCh4 false false Scalar READ Tango::DEV_DOUBLE OPERATOR
Backplane false false Scalar READ_WRITE Tango::DEV_STRING OPERATOR String for setting backplane when SetMeasurement is called. Format: 1911,1922,...
Temperature false false Scalar READ Tango::DEV_DOUBLE OPERATOR
Thermocouple false false Scalar READ_WRITE Tango::DEV_LONG OPERATOR Thermocouple type:
-1 -> if transducer not set to THERMOCOPLE, 0 -> J, 1 -> K, 2 -> T, 3 -> D, 4 -> R, 5 -> S, 6 -> B, 7 -> N
Units false false Scalar READ_WRITE Tango::DEV_LONG OPERATOR -1 not meaning for set configuration, 0 -> volts, 1 -> decibels,
2 -> celsius, 3 -> kelvin, 4 -> fahrenheit
ValueCh5 false false Scalar READ Tango::DEV_DOUBLE OPERATOR
ValueCh6 false false Scalar READ Tango::DEV_DOUBLE OPERATOR
ValueCh7 false false Scalar READ Tango::DEV_DOUBLE OPERATOR
ValueCh8 false false Scalar READ Tango::DEV_DOUBLE OPERATOR
ContinuousMeasurements false false Scalar READ_WRITE Tango::DEV_LONG OPERATOR Set to 1 for starting loop measuaring continuously.
KeithleyInitCommand false false Scalar READ_WRITE Tango::DEV_STRING OPERATOR Name of the file to be run by the RunKeihtleyInit command.
KeithleyCommand false false Scalar READ_WRITE Tango::DEV_STRING OPERATOR Command to be run by the RunKeithleyCommand command.
KeithleyCommandAnswer false false Scalar READ Tango::DEV_STRING OPERATOR Answer of the last performed Keithley Command
IntegrationRate false false Scalar READ_WRITE Tango::DEV_DOUBLE OPERATOR Integration rate in units of number of power line cycles (nplc)
OffsetCompensation false false Scalar READ_WRITE Tango::DEV_LONG OPERATOR OffsetCompensation: 0 -> off, 1 -> on, -1 -> not applicable in current configuration, -2 -> error reading
LineSync false false Scalar READ_WRITE Tango::DEV_LONG OPERATOR Line Sync: 0 -> off, 1 -> on, -1 -> not applicable in current configuration, -2 -> error reading
DataCh1 false false Spectrum READ Tango::DEV_DOUBLE OPERATOR Result of the measurement.
DataCh2 false false Spectrum READ Tango::DEV_DOUBLE OPERATOR Result of the measurement.
DataCh3 false false Spectrum READ Tango::DEV_DOUBLE OPERATOR Result of the measurement.
DataCh4 false false Spectrum READ Tango::DEV_DOUBLE OPERATOR Result of the measurement.
Data false false Spectrum READ Tango::DEV_DOUBLE OPERATOR Result of the measurement.





There is no dynamic attribute defined.