LKS336TempCtrl Class Attributes
Name
Inherited
Abstract
Attr. type
R/W type
Data type
Level
Description
OutputChannelA false false Scalar READ Tango::DEV_DOUBLE OPERATOR
SensorTypeA false false Scalar READ_WRITE Tango::DEV_LONG OPERATOR Sensor Type: 0->disabled,1->Diode,2->Platinum RTD,3->NTC RTD,4->Thermocouple
SensorTypeAInfo false false Scalar READ Tango::DEV_STRING OPERATOR
InputCurveA false false Scalar READ_WRITE Tango::DEV_LONG OPERATOR Input Curve for channel A.
TlimitA false false Scalar READ_WRITE Tango::DEV_LONG OPERATOR A temperature limit in Kelvin for which to shutdown all control outputs when exceeded.\n0-> turns this feature off.
OutputChannelB false false Scalar READ Tango::DEV_DOUBLE OPERATOR
SensorTypeB false false Scalar READ_WRITE Tango::DEV_LONG OPERATOR Sensor Type: 0->disabled,1->Diode,2->Platinum RTD,3->NTC RTD,4->Thermocouple
SensorTypeBInfo false false Scalar READ Tango::DEV_STRING OPERATOR
InputCurveB false false Scalar READ_WRITE Tango::DEV_LONG OPERATOR Input Curve for channel B.
TlimitB false false Scalar READ_WRITE Tango::DEV_LONG OPERATOR A temperature limit in Kelvin for which to shutdown all control outputs when exceeded.\n0-> turns this feature off.
OutputChannelC false false Scalar READ Tango::DEV_DOUBLE OPERATOR
SensorTypeC false false Scalar READ_WRITE Tango::DEV_LONG OPERATOR Sensor Type: 0->disabled,1->Diode,2->Platinum RTD,3->NTC RTD,4->Thermocouple
SensorTypeCInfo false false Scalar READ Tango::DEV_STRING OPERATOR
InputCurveC false false Scalar READ_WRITE Tango::DEV_LONG OPERATOR Input Curve for channel C,
TlimitC false false Scalar READ_WRITE Tango::DEV_LONG OPERATOR A temperature limit in Kelvin for which to shutdown all control outputs when exceeded.\n0-> turns this feature off.
OutputChannelD false false Scalar READ Tango::DEV_DOUBLE OPERATOR
SensorTypeD false false Scalar READ_WRITE Tango::DEV_LONG OPERATOR Sensor Type: 0->disabled,1->Diode,2->Platinum RTD,3->NTC RTD,4->Thermocouple
SensorTypeDInfo false false Scalar READ Tango::DEV_STRING OPERATOR
InputCurveD false false Scalar READ_WRITE Tango::DEV_LONG OPERATOR Input Curve for channel D,
TlimitD false false Scalar READ_WRITE Tango::DEV_LONG OPERATOR A temperature limit in Kelvin for which to shutdown all control outputs when exceeded.\n0-> turns this feature off.
ResistanceH1 false false Scalar READ_WRITE Tango::DEV_LONG OPERATOR 1->25Ohms, 2->50Ohms
ControlModeH1 false false Scalar READ_WRITE Tango::DEV_LONG OPERATOR 0= Off\n1= Close loop PID\n2= Zone\n3= Open loop\n4= Monitor out\n5= Warmup supply
ControlModeH1Info false false Scalar READ Tango::DEV_STRING OPERATOR
ControlChannelH1 false false Scalar READ_WRITE Tango::DEV_LONG OPERATOR 0->none,1->A,2->B,3->C,4->D
ProportionalH1 false false Scalar READ_WRITE Tango::DEV_FLOAT OPERATOR Proportional parameter (also called gain).
IntegralH1 false false Scalar READ_WRITE Tango::DEV_FLOAT OPERATOR Integral parameter (also called reset).
DerivativeH1 false false Scalar READ_WRITE Tango::DEV_LONG OPERATOR Derivative parameter (also called rate).
SetPointH1 false false Scalar READ_WRITE Tango::DEV_DOUBLE OPERATOR Temperature Setpoint
RampRateH1 false false Scalar READ_WRITE Tango::DEV_DOUBLE OPERATOR
HeaterRangeH1 false false Scalar READ_WRITE Tango::DEV_LONG OPERATOR Heater Range: 0 to 5.
ResistanceH2 false false Scalar READ_WRITE Tango::DEV_LONG OPERATOR 1->25Ohms, 2->50Ohms
ControlModeH2 false false Scalar READ_WRITE Tango::DEV_LONG OPERATOR 0= Off\n1= Close loop PID\n2= Zone\n3= Open loop\n4= Monitor out\n5= Warmup supply
ControlModeH2Info false false Scalar READ Tango::DEV_STRING OPERATOR
ControlChannelH2 false false Scalar READ_WRITE Tango::DEV_LONG OPERATOR 0->none,1->A,2->B,3->C,4->D
ProportionalH2 false false Scalar READ_WRITE Tango::DEV_FLOAT OPERATOR Proportional parameter (also called gain).
IntegralH2 false false Scalar READ_WRITE Tango::DEV_FLOAT OPERATOR Integral parameter (also called reset).
DerivativeH2 false false Scalar READ_WRITE Tango::DEV_LONG OPERATOR Derivative parameter (also called rate).
SetPointH2 false false Scalar READ_WRITE Tango::DEV_DOUBLE OPERATOR Temperature Setpoint
RampRateH2 false false Scalar READ_WRITE Tango::DEV_DOUBLE OPERATOR
HeaterRangeH2 false false Scalar READ_WRITE Tango::DEV_LONG OPERATOR Heater Range: 0 to 5.
Tmax false false Scalar READ_WRITE Tango::DEV_DOUBLE OPERATOR Attribute only to write and read.
RampOffOnH1 false false Scalar READ_WRITE Tango::DEV_LONG OPERATOR
RampOffOnH2 false false Scalar READ_WRITE Tango::DEV_LONG OPERATOR
CurvesInfo false false Spectrum READ Tango::DEV_STRING OPERATOR Information about curves and the allowed sensor types and temperature ranges.





There is no dynamic attribute defined.