| SetPointA | false | false | Scalar | READ_WRITE | Tango::DEV_DOUBLE | OPERATOR | Set point A value unit depends on AbsoluteValues setting: if true, value is pressure if false, value is % of full scale range |
| AbsoluteValues | false | false | Scalar | READ_WRITE | Tango::DEV_BOOLEAN | OPERATOR | The controller returns values for presssure settings (pressure, setpoint, process limit) in % of full range. If you want the real values calculated set this to true. |
| SetPointB | false | false | Scalar | READ_WRITE | Tango::DEV_DOUBLE | OPERATOR | Set point B value unit depends on AbsoluteValues setting: if true, value is pressure if false, value is % of full scale range |
| SetPointC | false | false | Scalar | READ_WRITE | Tango::DEV_DOUBLE | OPERATOR | Set point C value unit depends on AbsoluteValues setting: if true, value is pressure if false, value is % of full scale range |
| SetPointD | false | false | Scalar | READ_WRITE | Tango::DEV_DOUBLE | OPERATOR | Set point D value unit depends on AbsoluteValues setting: if true, value is pressure if false, value is % of full scale range |
| SetPointE | false | false | Scalar | READ_WRITE | Tango::DEV_DOUBLE | OPERATOR | Set point E value unit depends on AbsoluteValues setting: if true, value is pressure if false, value is % of full scale range |
| SetPointAnalogue | false | false | Scalar | READ_WRITE | Tango::DEV_DOUBLE | OPERATOR | Analogue set point A value unit depends on AbsoluteValues setting: if true, value is pressure if false, value is % of full scale range |
| SelectedSetPoint | false | false | Scalar | READ_WRITE | Tango::DEV_USHORT | OPERATOR | Selected setpoint: 0 = analogue 1 = A 2 = B 3 = C 4 = D 5 = E |
| Unit | false | false | Scalar | READ_WRITE | Tango::DEV_USHORT | OPERATOR | Pressure Unit: 0 = Torr 1 = mTorr 2 = mbar 3 = nbar 4 = kPa 5 = Pa 6 = cmH2O 7 = inH2O This just changes the unit sign displayed on the device. Check / set SensorPressureRange value as well. |
| SensorPressureRange | false | false | Scalar | READ_WRITE | Tango::DEV_USHORT | OPERATOR | Sensor pressure range: 0 = 0.1 1 = 0.2 2 = 0.5 3 = 1.0 4 = 2.0 5 = 5.0 6 = 10.0 7 = 50.0 8 = 100.0 9 = 500.0 10 = 1000.0 11 = 5000.0 12 = 10000.0 13 = 1.33 14 = 2.66 15 = 13.33 16 = 133.3 17 = 1333.0 18 = 6666.0 19 = 13332.0 |
| SensorVoltageRange | false | false | Scalar | READ_WRITE | Tango::DEV_USHORT | OPERATOR | Sensor voltage range: 0 = 1 V 1 = 5 V 2 = 10 V |
| ValveState | false | false | Scalar | READ_WRITE | Tango::DEV_USHORT | OPERATOR | Valve State: 0 = open 1 = close 2 = stop |
| SoftStartA | false | false | Scalar | READ_WRITE | Tango::DEV_DOUBLE | OPERATOR | softstart rate of set point A, value is % of full speed |
| SoftStartB | false | false | Scalar | READ_WRITE | Tango::DEV_DOUBLE | OPERATOR | softstart rate of set point B, value is % of full speed |
| SoftStartC | false | false | Scalar | READ_WRITE | Tango::DEV_DOUBLE | OPERATOR | softstart rate of set point C, value is % of full speed |
| SoftStartD | false | false | Scalar | READ_WRITE | Tango::DEV_DOUBLE | OPERATOR | softstart rate of set point D, value is % of full speed |
| SoftStartE | false | false | Scalar | READ_WRITE | Tango::DEV_DOUBLE | OPERATOR | softstart rate of set point E, value is % of full speed |
| SoftStartAnalogue | false | false | Scalar | READ_WRITE | Tango::DEV_DOUBLE | OPERATOR | softstart rate of analog set point, value is % of full speed |
| SoftStartValveOpen | false | false | Scalar | READ_WRITE | Tango::DEV_DOUBLE | OPERATOR | softstart rate of open valve, value is % of full speed |
| SoftStartValveClose | false | false | Scalar | READ_WRITE | Tango::DEV_DOUBLE | OPERATOR | softstart rate of close valve, value is % of full speed |
| ProcessLimit1Low | false | false | Scalar | READ_WRITE | Tango::DEV_DOUBLE | OPERATOR | low threshold process limit 1 unit depends on AbsoluteValues setting: if true, value is pressure if false, value is % of full scale range |
| ProcessLimit1High | false | false | Scalar | READ_WRITE | Tango::DEV_DOUBLE | OPERATOR | high threshold process limit 1 unit depends on AbsoluteValues setting: if true, value is pressure if false, value is % of full scale range |
| ProcessLimit2Low | false | false | Scalar | READ_WRITE | Tango::DEV_DOUBLE | OPERATOR | low threshold process limit 2 unit depends on AbsoluteValues setting: if true, value is pressure if false, value is % of full scale range |
| ProcessLimit2High | false | false | Scalar | READ_WRITE | Tango::DEV_DOUBLE | OPERATOR | high threshold process limit 2 unit depends on AbsoluteValues setting: if true, value is pressure if false, value is % of full scale range |
| AnalogueSetPointRange | false | false | Scalar | READ_WRITE | Tango::DEV_USHORT | OPERATOR | Sensor pressure range: 0 = 0.1 1 = 0.2 2 = 0.5 3 = 1.0 4 = 2.0 5 = 5.0 6 = 10.0 7 = 50.0 8 = 100.0 9 = 500.0 10 = 1000.0 11 = 5000.0 12 = 10000.0 13 = 1.33 14 = 2.66 15 = 13.33 16 = 133.3 17 = 1333.0 18 = 6666.0 19 = 13332.0 |
| SetPointAnalogueType | false | false | Scalar | READ_WRITE | Tango::DEV_USHORT | OPERATOR | Set point A type where value is: 0 = position 1 = pressure |
| SetPointBType | false | false | Scalar | READ_WRITE | Tango::DEV_USHORT | OPERATOR | Set point A type where value is: 0 = position 1 = pressure |
| SetPointCType | false | false | Scalar | READ_WRITE | Tango::DEV_USHORT | OPERATOR | Set point A type where value is: 0 = position 1 = pressure |
| SetPointDType | false | false | Scalar | READ_WRITE | Tango::DEV_USHORT | OPERATOR | Set point A type where value is: 0 = position 1 = pressure |
| SetPointEType | false | false | Scalar | READ_WRITE | Tango::DEV_USHORT | OPERATOR | Set point A type where value is: 0 = position 1 = pressure |
| SetPointAType | false | false | Scalar | READ_WRITE | Tango::DEV_USHORT | OPERATOR | Set point A type where value is: 0 = position 1 = pressure |
| ValvePositionOutputRange | false | false | Scalar | READ_WRITE | Tango::DEV_USHORT | OPERATOR | Valve position output range: 0 = 5 V 1 = 10 V |
| DirectReverseControl | false | false | Scalar | READ_WRITE | Tango::DEV_USHORT | OPERATOR | Direct / Reverse control: 0 = direct 1 = reverse |
| SensorType | false | false | Scalar | READ_WRITE | Tango::DEV_USHORT | OPERATOR | Sensor type: 0 = absolut 1 = differential |
| LeadA | false | false | Scalar | READ_WRITE | Tango::DEV_DOUBLE | OPERATOR | Lead for Setpoint A |
| GainA | false | false | Scalar | READ_WRITE | Tango::DEV_DOUBLE | OPERATOR | gain of Setpoint A, where value = % gain |
| LeadB | false | false | Scalar | READ_WRITE | Tango::DEV_DOUBLE | OPERATOR | Lead for SetpointB |
| LeadC | false | false | Scalar | READ_WRITE | Tango::DEV_DOUBLE | OPERATOR | Lead for Setpoint C |
| LeadD | false | false | Scalar | READ_WRITE | Tango::DEV_DOUBLE | OPERATOR | Lead for Setpoint D |
| LeadE | false | false | Scalar | READ_WRITE | Tango::DEV_DOUBLE | OPERATOR | Lead for Setpoint E |
| GainB | false | false | Scalar | READ_WRITE | Tango::DEV_DOUBLE | OPERATOR | gain of Setpoint B, where value = % gain |
| GainC | false | false | Scalar | READ_WRITE | Tango::DEV_DOUBLE | OPERATOR | gain of SetpointC, where value = % gain |
| GainD | false | false | Scalar | READ_WRITE | Tango::DEV_DOUBLE | OPERATOR | gain of SetpointD, where value = % gain |
| GainE | false | false | Scalar | READ_WRITE | Tango::DEV_DOUBLE | OPERATOR | gain of Setpoint E, where value = % gain |
| ControlType | false | false | Scalar | READ_WRITE | Tango::DEV_BOOLEAN | OPERATOR | Control type: 0 = self-tuning 1 = PID |
| ValveOnPowerFail | false | false | Scalar | READ_WRITE | Tango::DEV_USHORT | OPERATOR | Behaviour of valve on power failure: 0 = option not activated or installed 1 = valve opens on power failure 2 = valve closes on power failure |
| ValveType | false | false | Scalar | READ_WRITE | Tango::DEV_USHORT | OPERATOR | Sensor type: 0 = absolut 1 = differential |
| Pressure | false | false | Scalar | READ | Tango::DEV_DOUBLE | OPERATOR | |
| ValvePosition | false | false | Scalar | READ | Tango::DEV_DOUBLE | OPERATOR | |