Magnet622 Class Attributes
Name
Inherited
Abstract
Attr. type
R/W type
Data type
Level
Description
PhiTarget false false Scalar READ_WRITE Tango::DEV_DOUBLE OPERATOR Get/set the target phi angle of the magnetic field (B), used in Spherical mode
ThetaTarget false false Scalar READ_WRITE Tango::DEV_DOUBLE OPERATOR Get/set the target theta angle of the magnetic field (B), used in Spherical mode.
(Commands VM_setTargetTheta / VM_getTargetTheta)
TemperatureTarget false false Scalar READ_WRITE Tango::DEV_DOUBLE OPERATOR write / read the target needle valve cell temperature
Output1TargetTemperature false false Scalar READ_WRITE Tango::DEV_DOUBLE OPERATOR read / write the target temperature for output 1
Output2TargetTemperature false false Scalar READ_WRITE Tango::DEV_DOUBLE OPERATOR read / write the target temperature for output 2
Output3TargetTemperature false false Scalar READ_WRITE Tango::DEV_DOUBLE OPERATOR read / write the target temperature for output 3
Output4TargetTemperature false false Scalar READ_WRITE Tango::DEV_DOUBLE OPERATOR read / write the target temperature for output 4
SensorA false false Scalar READ Tango::DEV_DOUBLE OPERATOR read / write the value for sensor A
SensorB false false Scalar READ Tango::DEV_DOUBLE OPERATOR read / write the value for sensor B
SensorC false false Scalar READ Tango::DEV_DOUBLE OPERATOR read / write the value for sensor C
SensorD false false Scalar READ Tango::DEV_DOUBLE OPERATOR read / write the value for sensor D
CoordinateSystem false false Scalar READ_WRITE Tango::DEV_BOOLEAN OPERATOR write / read the coordinate to either Cartesian (0) or Spherical (1)
TimeToTarget false false Scalar READ Tango::DEV_DOUBLE OPERATOR Get the time to target in units of seconds
PathCalculationType false false Scalar READ_WRITE Tango::DEV_LONG OPERATOR write the Path Calculation Type. (0) Calculate by time, (1) Calculate by Ramp rate
PersistentMode false false Scalar READ_WRITE Tango::DEV_BOOLEAN OPERATOR write / read the magnet persistent mode (true = on, false = off)
RotationDirection false false Scalar READ_WRITE Tango::DEV_LONG OPERATOR write / read the rotation direction if coordinate system is in Spherical mode
0 = anticlockwise, 1= clockwise
RotationAxisType false false Scalar READ_WRITE Tango::DEV_LONG OPERATOR write / read the rotation axis type.
If Z-axis (2) then the rotation will be about Z. if AxB (3) then it would
rotate about the axis that is perpendicular to the initial and final vector.
MagnetReady false false Scalar READ Tango::DEV_BOOLEAN OPERATOR read the ready status of the Vector Magnet(true = ready, false = not ready) If it is not ready
then do not perform any path calculation or ramp.
RampTime false false Scalar READ_WRITE Tango::DEV_DOUBLE OPERATOR write / read the ramp time needed if Path calculation type (PathCalculationType) is set to calculate by time.
Theta false false Scalar READ Tango::DEV_DOUBLE OPERATOR read the theta angle of the magnetic field (B), used in Spherical mode.
XFieldAmps false false Scalar READ Tango::DEV_DOUBLE OPERATOR read the value of the X field in Amps
XFieldTesla false false Scalar READ Tango::DEV_DOUBLE OPERATOR read the value of the X field in Tesla
TargetXFieldTesla false false Scalar READ_WRITE Tango::DEV_DOUBLE OPERATOR write / read the value of the Target X field in Tesla
XFieldRampRate false false Scalar READ_WRITE Tango::DEV_DOUBLE OPERATOR write / read the X field Ramp rate, in units of A/s
YFieldAmps false false Scalar READ_WRITE Tango::DEV_DOUBLE OPERATOR read the value of the Y field in Amps
YFieldTesla false false Scalar READ_WRITE Tango::DEV_DOUBLE OPERATOR read the value of the Y field in Tesla
TargetYFieldTesla false false Scalar READ_WRITE Tango::DEV_DOUBLE OPERATOR write / read the value of the Target Y field in Tesla
YFieldRampRate false false Scalar READ_WRITE Tango::DEV_DOUBLE OPERATOR write / read the Y field Ramp rate, in units of A/s
ZFieldAmps false false Scalar READ_WRITE Tango::DEV_DOUBLE OPERATOR read the value of the Z field in Amps
ZFieldTesla false false Scalar READ_WRITE Tango::DEV_DOUBLE OPERATOR read the value of the Z field in Tesla
ZFieldRampRate false false Scalar READ_WRITE Tango::DEV_DOUBLE OPERATOR write / read the Z field Ramp rate, in units of A/s
TargetZFieldTesla false false Scalar READ_WRITE Tango::DEV_DOUBLE OPERATOR write / read the value of the Target Z field in Tesla
MotorAngle false false Scalar READ_WRITE Tango::DEV_DOUBLE OPERATOR write / read the angle of the rotation motor
MotorHeight false false Scalar READ_WRITE Tango::DEV_DOUBLE OPERATOR write / read the height of the vertical motor
MotionStatus false false Scalar READ Tango::DEV_LONG OPERATOR read the motion status of motors.
0 = No motion
1 = Vertical motion
2 = Rotation motion
HeightAtTarget false false Scalar READ Tango::DEV_BOOLEAN OPERATOR check whether height is at target position

true = yes

false = no
RotationAtTarget false false Scalar READ Tango::DEV_BOOLEAN OPERATOR check whether rotation is at target position

true = yes

false = no
Temperature false false Scalar READ Tango::DEV_DOUBLE OPERATOR read the temperature of the needle valve cell
Pressure false false Scalar READ Tango::DEV_DOUBLE OPERATOR read the the pressure
DumpPressure false false Scalar READ Tango::DEV_DOUBLE OPERATOR read the dump pressure
OutputPower false false Scalar READ Tango::DEV_DOUBLE OPERATOR read the output power
MagneticField false false Scalar READ Tango::DEV_DOUBLE OPERATOR read the magnitude of the magnetic field, used in Spherical mode
MagneticFieldTarget false false Scalar READ_WRITE Tango::DEV_DOUBLE OPERATOR write / read the magnitude of the target magnetic field, used in Spherical mode
PhiAngle false false Scalar READ Tango::DEV_DOUBLE OPERATOR Get the phi angle of the magnetic field (B), used in Spherical mode
UserRotationAngle false false Scalar READ_WRITE Tango::DEV_DOUBLE OPERATOR write / read the user rotation angle
ControllerStatus false false Scalar READ Tango::DEV_STRING OPERATOR Display the current status message in the Status field at the bottom of the Temperature Control window on the Windows PC
Temperatures false false Spectrum READ Tango::DEV_DOUBLE OPERATOR Returns a list of temperature sensor values in the order shown in the Temperature Monitor.





There is no dynamic attribute defined.