| OxfordCryostream700 Class Attributes |
| Name |
Inherited |
Abstract |
Attr. type |
R/W type |
Data type |
Level |
Description |
| GasSetPoint |
false |
false |
Scalar |
READ |
Tango::DEV_FLOAT |
OPERATOR |
Set temperature. |
| GasTemp |
false |
false |
Scalar |
READ |
Tango::DEV_FLOAT |
OPERATOR |
Current gas temperature. |
| GasError |
false |
false |
Scalar |
READ |
Tango::DEV_FLOAT |
EXPERT |
Difference between current and set temperature. |
| RunMode |
false |
false |
Scalar |
READ |
Tango::DEV_STRING |
EXPERT |
RunMode of the cryo controller (StartUp, StartUpFail, StartUpOk, Run, SetUp, ShutdownOk, ShutdownFail). |
| Phase |
false |
false |
Scalar |
READ |
Tango::DEV_STRING |
EXPERT |
Program Phase of the cryo controller (Ramp, Cool, Plat, Hold, End, Purge, Soak, Wait). This parameter is meaningless unless RunMode is Run. |
| RampRate |
false |
false |
Scalar |
READ |
Tango::DEV_USHORT |
OPERATOR |
Cooling ramp rate for the current program phase. |
| TargetTemp |
false |
false |
Scalar |
READ_WRITE |
Tango::DEV_FLOAT |
OPERATOR |
Temperature set point for the current program phase. If a value is written, the device will ramp up with 360K/h or cool down to it. |
| Remaining |
false |
false |
Scalar |
READ |
Tango::DEV_USHORT |
EXPERT |
Time remaining in current program phase. |
| GasFlow |
false |
false |
Scalar |
READ |
Tango::DEV_FLOAT |
OPERATOR |
Current gas flow. |
| GasHeat |
false |
false |
Scalar |
READ |
Tango::DEV_UCHAR |
EXPERT |
Current gas heating. |
| LinePressure |
false |
false |
Scalar |
READ |
Tango::DEV_FLOAT |
EXPERT |
Current back pressure. |
| Alarm |
false |
false |
Scalar |
READ |
Tango::DEV_STRING |
OPERATOR |
Indicator for most serious alarm conditions. |
| RunTime |
false |
false |
Scalar |
READ |
Tango::DEV_STRING |
EXPERT |
Uptime of the pump. |
| ControllerNumber |
false |
false |
Scalar |
READ |
Tango::DEV_USHORT |
EXPERT |
Serial number of the controller device. |
| SoftwareVersion |
false |
false |
Scalar |
READ |
Tango::DEV_UCHAR |
EXPERT |
Firmware version of the controller device. |
| Hardware |
false |
false |
Scalar |
READ |
Tango::DEV_STRING |
EXPERT |
Connected controller and cooler system devices. |
| OxfordCryostream700 Class Dynamic Attributes |
| Name |
Inherited |
Abstract |
Attr. type |
R/W type |
Data type |
Level |
Description |
| ColdheadSerial |
false |
false |
Scalar |
READ |
Tango::DEV_USHORT |
EXPERT |
N-Helix coldhead serial number. |
| EvapTemp |
false |
false |
Scalar |
READ |
Tango::DEV_FLOAT |
EXPERT |
Current evaporator temperature. |
| SuctTemp |
false |
false |
Scalar |
READ |
Tango::DEV_FLOAT |
EXPERT |
Current SUCT temperature. |
| RefrTemp |
false |
false |
Scalar |
READ |
Tango::DEV_FLOAT |
EXPERT |
Current refrigerator temperature. |
| ShieldTemp |
false |
false |
Scalar |
READ |
Tango::DEV_DOUBLE |
EXPERT |
Current shield temperature. |
| NozzleTemp |
false |
false |
Scalar |
READ |
Tango::DEV_FLOAT |
EXPERT |
Current nozzle temperature. |
| WaterTemp |
false |
false |
Scalar |
READ |
Tango::DEV_FLOAT |
EXPERT |
Cryodrive water temp. |
| EvapHeat |
false |
false |
Scalar |
READ |
Tango::DEV_UCHAR |
EXPERT |
Current evaporator heating. |
| SuctHeat |
false |
false |
Scalar |
READ |
Tango::DEV_UCHAR |
EXPERT |
Current SUCT heating. |
| RefrHeat |
false |
false |
Scalar |
READ |
Tango::DEV_UCHAR |
EXPERT |
Current refrigerator heating. |
| ShieldHeat |
false |
false |
Scalar |
READ |
Tango::DEV_UCHAR |
EXPERT |
Current shield heating. |
| NozzleHeat |
false |
false |
Scalar |
READ |
Tango::DEV_BOOLEAN |
EXPERT |
Nozzle heater value (on / off). |
| AverageGasHeat |
false |
false |
Scalar |
READ |
Tango::DEV_UCHAR |
EXPERT |
Average value of gas heater. |
| AverageSuctHeat |
false |
false |
Scalar |
READ |
Tango::DEV_UCHAR |
EXPERT |
Average value of SUCT heater. |
| AverageNozzleHeat |
false |
false |
Scalar |
READ |
Tango::DEV_UCHAR |
EXPERT |
Average value of nozzle heater. |
| EvapAdjust |
false |
false |
Scalar |
READ |
Tango::DEV_BOOLEAN |
EXPERT |
Evaporator adjusts vacuum compensation. |
| TurboMode |
false |
false |
Scalar |
READ |
Tango::DEV_BOOLEAN |
EXPERT |
Turbo mode is active. The gas flow is increased to 10 l/min. |
| ShutterState |
false |
false |
Scalar |
READ |
Tango::DEV_BOOLEAN |
OPERATOR |
Cryo shutter is closed. |
| ShutterTime |
false |
false |
Scalar |
READ |
Tango::DEV_FLOAT |
OPERATOR |
Remaining anneal time. |
| DewarLevel |
false |
false |
Scalar |
READ |
Tango::DEV_UCHAR |
EXPERT |
Current Dewar level. |
| TimeToFill |
false |
false |
Scalar |
READ |
Tango::DEV_USHORT |
EXPERT |
Estimated time to the next Dewar refill. |
| Vacuum |
false |
false |
Scalar |
READ |
Tango::DEV_FLOAT |
EXPERT |
The pressure measured by the vacuum gauge. |
| VacuumGaugePower |
false |
false |
Scalar |
READ |
Tango::DEV_UCHAR |
EXPERT |
Power to vacuum gauge. |
| HePressure |
false |
false |
Scalar |
READ |
Tango::DEV_FLOAT |
EXPERT |
Cryodrive He pressure |
| SupplyPressure |
false |
false |
Scalar |
READ |
Tango::DEV_FLOAT |
EXPERT |
The pressure of the supplied gas. |
| CryoStatus |
false |
false |
Scalar |
READ |
Tango::DEV_STRING |
EXPERT |
An indication of the status of the Cryodrive. |
| CryoShift |
false |
false |
Scalar |
READ |
Tango::DEV_UCHAR |
EXPERT |
A parameter indicating the amount by which the Cryodrive speed has
been increased to allow very low temperatures to be attained. |
| CryoSpeed |
false |
false |
Scalar |
READ |
Tango::DEV_UCHAR |
EXPERT |
The current Cryodrive speed. |
| Suspend |
false |
false |
Scalar |
READ |
Tango::DEV_BOOLEAN |
EXPERT |
Flag to indicate device is in temporary Hold. |
| OuterFlow |
false |
false |
Scalar |
READ |
Tango::DEV_DOUBLE |
EXPERT |
Current flow rate in outer stream. |
| DetectedGasType |
false |
false |
Scalar |
READ |
Tango::DEV_STRING |
EXPERT |
Detected gas in cold stream. |
| SelectedGasType |
false |
false |
Scalar |
READ |
Tango::DEV_STRING |
EXPERT |
Selected gas in coldstream. |
| TotalHours |
false |
false |
Scalar |
READ |
Tango::DEV_USHORT |
EXPERT |
Total number of hours device has run. |