FileToLoad | false | false | Scalar | READ_WRITE | Tango::DEV_STRING | OPERATOR | Full path of the file with the arrays generating the triggers |
Arm | false | false | Scalar | READ_WRITE | Tango::DEV_LONG | OPERATOR | Set to 1 to start triggering and 0 to stop. |
CurrentEncoderValue | false | false | Scalar | READ | Tango::DEV_LONG | OPERATOR | |
CurrentCounterValue | false | false | Scalar | READ | Tango::DEV_LONG | OPERATOR | |
Signal1CounterValue | false | false | Scalar | READ | Tango::DEV_LONG | OPERATOR | |
Signal1NextPoint | false | false | Scalar | READ | Tango::DEV_DOUBLE | OPERATOR | |
Signal2CounterValue | false | false | Scalar | READ | Tango::DEV_LONG | OPERATOR | |
Signal2NextPoint | false | false | Scalar | READ | Tango::DEV_DOUBLE | OPERATOR | |
Signal3CounterValue | false | false | Scalar | READ | Tango::DEV_LONG | OPERATOR | |
Signal3NextPoint | false | false | Scalar | READ | Tango::DEV_DOUBLE | OPERATOR | |
Signal4CounterValue | false | false | Scalar | READ | Tango::DEV_LONG | OPERATOR | |
Signal4NextPoint | false | false | Scalar | READ | Tango::DEV_DOUBLE | OPERATOR | |
PositionConversion | false | false | Scalar | READ_WRITE | Tango::DEV_DOUBLE | OPERATOR | Conversion from enconder values to physical units: steps = conversion*units |
CurrentPosition | false | false | Scalar | READ | Tango::DEV_DOUBLE | OPERATOR | |
Mode | false | false | Scalar | READ_WRITE | Tango::DEV_LONG | OPERATOR | 0 -> counter mode, 1 -> encoder mode |
OutPolarity | false | false | Scalar | READ_WRITE | Tango::DEV_LONG | OPERATOR | Decimal representation for setting the bits for the inversion of the output signals. If 0, not inversion is done, if 255 all eight output signals are inverted, if 3 signals 1 and 2 are inverted, ... |