If this device is used for general scans, the sample time may exceed 10 seconds. The software restarts the timer, if needed.
This timer cannot be stopped.
If this module is used with the V260 counter the gate output has to be inverted, e.g. by a N454.
A V462 board is introduced to Online by:
define/dev=timer/mod=v462/base=0x0/vector=0/chan=0 t1 define/dev=timer/mod=v462/base=0x0/vector=0/chan=1 t2