Attributes

pogo_html_docu/ZMX/Attributes.html See pogo generated info for more details.
 AxisName. Read/Write user defined name for the axis.
 Channel_rd. Read power stage channel number (as given in the property channel).
 Deactivation. Read/Write deactivation. 0 = activated, 1 = deactivated.
 DeactivationStr. Read Deactivation and show the value as a meanfull string.
 DelayTime. Read/Write delay time. Read value in ms. Valid write values: from 0 to 15. set_value=real_value(ms) O=1, 1=2, 2=4, 3=6, 4=8, 5=10, 6=12, 7=14, 8=16, 9=20, 10=40, 11=60, 12=100, 13=200, 14=500, 15=1000.
 DelayTimeInfo. String for writing any info about the delay time.
 Error. Inquiry error from the power stage and return the corresponding description.
 ErrorZMXConnection. List of commands send to the ZMX and date when an connection error was produced. It is reset by executing the command ResetErrorZMXConnection or after 5 errors are produced. It uses the Checksum for detecting errors in writing or reading.
 FlagChangeNotSaved. If 1, some setting of the power stage has been changed (by writting to the corresponding attribute) and not write to EPROM was performed after that. Only read value.
 FlagErrorZMXConnection. It is 1 if an error was produced by reading/wrinting from/to the ZMS. It is reset to 0 by executing the command ResetErrorZMXConnection. It uses the Checksum for detecting errors in writing or reading.
 FlagSaveAutomatically. If set to 1 an automatic write to EPROM will be performed after some setting is changed (by writting to the corresponding attribute).
 FlagThreadRunning. 1 if the thread is running, in that case not read or write operation will be performed. Only read.
 HwDeactivation. 1 if hardware is not active. Only read.
 InputLogicLevel. Read/Write logic level of all inputs. 0 = high, 1 = low.
 InputLogicLevelStr. Read InputLogicLevel and show the value as a meanfull string.
 IntermediateVoltage. Read intermediate voltage (in V).
 IntermediateVoltageInfo. String for writing any info about the intermediate voltage.
 OperationMode. Status Service Bus. 0 = off, 1 = on. The Service Bus status is activated in ZMX+ power stage by the 'SB active' DIP switch. By software one can only read the status.
 OperationModeStr. Read OperationMode and show the value as a meanfull string.
 Overdrive. Read/Write overdrive. 0 = on, 1 = off.
 OverdriveStr. Read Overdrive and show the value as a meanfull string.
 PathOutputFiles. Path where the commands SaveToOutputFile, LoadFromOutputFile, ReadFileContent and ReadFilesInOutputPath are performed.
 PowerStageStatus. Read the current status of the power stage and return the corresponding description.
 PreferentialDirection. Read/Write preferential direction. 1=preferential direction, 0=contrary to preferential direction.
 PreferentialDirectionStr. Read PreferentialDirection and show the value as a meanfull string.
 RunCurrent. Read/Write the run current (in A).
 StepWidth. Read/Write step width. Valid values: 0 to 13. 0=1/1, 2=1/2, 3=1/4, 4=1/5, 5=1/8, 6=1/10, 7=1/16, 8=1/20, 9=1/32, 10=1/64, 11=1/128, 12=1/256, 13=512.
 StepWidthStr. Read real value of step width in string format.
 StopCurrent. Read/Write the stop current (in A).
 Temperature. Read current temperature from the power stage (in degrees).
 VersionFPGA. Show version of the FPGA.
 VersionPS. Show version of the Power Stage.