25 Device Attributes
|
Name
|
Inherited
|
Abstract
|
Attr. type
|
R/W type
|
Data type
|
Level
|
Description
|
BiasSetpoint |
false |
false |
Scalar |
READ_WRITE |
Tango::DEV_DOUBLE |
OPERATOR |
Bias setpoint of the head in v. |
HeadState |
false |
false |
Scalar |
READ |
Tango::DEV_STRING |
OPERATOR |
Head state. |
SCAMode |
false |
false |
Scalar |
READ_WRITE |
Tango::DEV_STRING |
OPERATOR |
Mode of the SCA: INT or WIN |
SCALowTh |
false |
false |
Scalar |
READ_WRITE |
Tango::DEV_DOUBLE |
OPERATOR |
Low level discriminator level. |
SCAWinTh |
false |
false |
Scalar |
READ_WRITE |
Tango::DEV_DOUBLE |
OPERATOR |
Window width (only used in WIN mode). |
RateWin |
false |
false |
Scalar |
READ |
Tango::DEV_DOUBLE |
EXPERT |
Rate meter value in WIN mode. |
RateInt |
false |
false |
Scalar |
READ |
Tango::DEV_DOUBLE |
EXPERT |
Rate meter value in INT mode. |
HVState |
false |
false |
Scalar |
READ_WRITE |
Tango::DEV_STRING |
EXPERT |
|
HeadTemperature |
false |
false |
Scalar |
READ |
Tango::DEV_DOUBLE |
EXPERT |
Temperature of the head. Range of measurement from 0 to 50 C with a resolution of 0.05 C. |
HeadCurrent |
false |
false |
Scalar |
READ |
Tango::DEV_DOUBLE |
EXPERT |
Current of bias voltage of the head. Range from 0 to 11 uA, with a resolution of 24nA. |
CountingSource |
false |
false |
Scalar |
READ_WRITE |
Tango::DEV_STRING |
OPERATOR |
Selects/Returns the current counting source: SCA or TRG |
Counts |
false |
false |
Scalar |
READ |
Tango::DEV_LONG |
OPERATOR |
|
HeadVoltage |
false |
false |
Scalar |
READ |
Tango::DEV_DOUBLE |
OPERATOR |
Bias voltage of the head. Range from 0 to 655 V, with a resolution of 0.6V |
CounterStatus |
false |
false |
Scalar |
READ |
Tango::DEV_STRING |
EXPERT |
|
ErrorInfo |
false |
false |
Scalar |
READ |
Tango::DEV_STRING |
EXPERT |
|
Version |
false |
false |
Scalar |
READ |
Tango::DEV_STRING |
EXPERT |
Firmware version |
SCAOutput |
false |
false |
Scalar |
READ_WRITE |
Tango::DEV_LONG |
OPERATOR |
Read/set the SCA output parameter. \nThis parameter is the time shaping of the SCA output in ns. \nPossible values: 5, 10, 20 or 30. |
ScanLowLimit |
false |
false |
Scalar |
READ_WRITE |
Tango::DEV_DOUBLE |
OPERATOR |
Used as low limit for the scan, |
ScanHighLimit |
false |
false |
Scalar |
READ_WRITE |
Tango::DEV_DOUBLE |
OPERATOR |
Used as high limit for the scan. |
ScanIntegrationTime |
false |
false |
Scalar |
READ_WRITE |
Tango::DEV_LONG |
OPERATOR |
Measuring time in the scan. |
ScanMode |
false |
false |
Scalar |
READ_WRITE |
Tango::DEV_STRING |
OPERATOR |
Mode for the SCAN: INT or WIN |
ScanWin |
false |
false |
Scalar |
READ_WRITE |
Tango::DEV_DOUBLE |
OPERATOR |
Window used for scanning in window mode. |
ScanStepSize |
false |
false |
Scalar |
READ_WRITE |
Tango::DEV_DOUBLE |
OPERATOR |
Step Size |
BiasSoftLimit |
false |
false |
Scalar |
READ_WRITE |
Tango::DEV_DOUBLE |
OPERATOR |
Software limit for the BiasSetpoint. |
ScanSpectrum |
false |
false |
Spectrum (1000) |
READ |
Tango::DEV_LONG |
OPERATOR |
Output of the scan |