25 Device Attributes
|
|
Name
|
Inherited
|
Abstract
|
Attr. type
|
R/W type
|
Data type
|
Level
|
Description
|
| BiasSetpoint |
false |
false |
Scalar |
READ_WRITE |
Tango::DEV_DOUBLE |
OPERATOR |
Bias setpoint of the head in v. |
| HeadState |
false |
false |
Scalar |
READ |
Tango::DEV_STRING |
OPERATOR |
Head state. |
| SCAMode |
false |
false |
Scalar |
READ_WRITE |
Tango::DEV_STRING |
OPERATOR |
Mode of the SCA: INT or WIN |
| SCALowTh |
false |
false |
Scalar |
READ_WRITE |
Tango::DEV_DOUBLE |
OPERATOR |
Low level discriminator level. |
| SCAWinTh |
false |
false |
Scalar |
READ_WRITE |
Tango::DEV_DOUBLE |
OPERATOR |
Window width (only used in WIN mode). |
| RateWin |
false |
false |
Scalar |
READ |
Tango::DEV_DOUBLE |
EXPERT |
Rate meter value in WIN mode. |
| RateInt |
false |
false |
Scalar |
READ |
Tango::DEV_DOUBLE |
EXPERT |
Rate meter value in INT mode. |
| HVState |
false |
false |
Scalar |
READ_WRITE |
Tango::DEV_STRING |
EXPERT |
|
| HeadTemperature |
false |
false |
Scalar |
READ |
Tango::DEV_DOUBLE |
EXPERT |
Temperature of the head. Range of measurement from 0 to 50 C with a resolution of 0.05 C. |
| HeadCurrent |
false |
false |
Scalar |
READ |
Tango::DEV_DOUBLE |
EXPERT |
Current of bias voltage of the head. Range from 0 to 11 uA, with a resolution of 24nA. |
| CountingSource |
false |
false |
Scalar |
READ_WRITE |
Tango::DEV_STRING |
OPERATOR |
Selects/Returns the current counting source: SCA or TRG |
| Counts |
false |
false |
Scalar |
READ |
Tango::DEV_LONG |
OPERATOR |
|
| HeadVoltage |
false |
false |
Scalar |
READ |
Tango::DEV_DOUBLE |
OPERATOR |
Bias voltage of the head. Range from 0 to 655 V, with a resolution of 0.6V |
| CounterStatus |
false |
false |
Scalar |
READ |
Tango::DEV_STRING |
EXPERT |
|
| ErrorInfo |
false |
false |
Scalar |
READ |
Tango::DEV_STRING |
EXPERT |
|
| Version |
false |
false |
Scalar |
READ |
Tango::DEV_STRING |
EXPERT |
Firmware version |
| SCAOutput |
false |
false |
Scalar |
READ_WRITE |
Tango::DEV_LONG |
OPERATOR |
Read/set the SCA output parameter. \nThis parameter is the time shaping of the SCA output in ns. \nPossible values: 5, 10, 20 or 30. |
| ScanLowLimit |
false |
false |
Scalar |
READ_WRITE |
Tango::DEV_DOUBLE |
OPERATOR |
Used as low limit for the scan, |
| ScanHighLimit |
false |
false |
Scalar |
READ_WRITE |
Tango::DEV_DOUBLE |
OPERATOR |
Used as high limit for the scan. |
| ScanIntegrationTime |
false |
false |
Scalar |
READ_WRITE |
Tango::DEV_LONG |
OPERATOR |
Measuring time in the scan. |
| ScanMode |
false |
false |
Scalar |
READ_WRITE |
Tango::DEV_STRING |
OPERATOR |
Mode for the SCAN: INT or WIN |
| ScanWin |
false |
false |
Scalar |
READ_WRITE |
Tango::DEV_DOUBLE |
OPERATOR |
Window used for scanning in window mode. |
| ScanStepSize |
false |
false |
Scalar |
READ_WRITE |
Tango::DEV_DOUBLE |
OPERATOR |
Step Size |
| BiasSoftLimit |
false |
false |
Scalar |
READ_WRITE |
Tango::DEV_DOUBLE |
OPERATOR |
Software limit for the BiasSetpoint. |
| ScanSpectrum |
false |
false |
Spectrum (1000) |
READ |
Tango::DEV_LONG |
OPERATOR |
Output of the scan |