Move/m1=.../m2=...

The command

ONLINE> move/m1=mot5/m2=mot6/m3=mot7/m4=mot8

invokes the menu which supports simultaneuou movements of up to four motors (table 7.5).


Table 7.4: The move/m1=.../m2=... Menu
 

   Motor: MOT5, MC1_Z, MC1_HOR
   Position:        456                 Move:   |               | [unit]
   Limits:          318.7359            460.5459
..............................................................................

   Motor: MOT6, MC1_Y, MC1_VER
   Position:        5.223813            Move:                     [unit]
   Limits:          -26.128             34.985
..............................................................................

   Motor: MOT7, MC1_ROT_X, MC1_TET
   Position:        11.76024            Move:                     [unit]
   Limits:          -11.21643           42.62756
..............................................................................

   Motor: MOT8, MC1_TIL
   Position:        0                   Move:                     [unit]
   Limits:          -1.79               1.584
..............................................................................

            PF1 - EXECUTE MOVE, PF4 - EXIT, SPACE BAR TO STOP MOVE


The menu shows the motor name, aliases, the current position and limits.

You may specify several movements and start them simultaneously by pressing PF1. They can be interrupted with the space bar.

PF4 (Ctrl-X) exits this menu.